Sensor Calibration
© 2009 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · eMail: info.ecs@hirschmann.de · www.hirschmann.com 15
24 183 69 1012e (Generic) / 2009-02-26 / Rev. 01 / rk.
Boom down.
Release adjustment screws of the angle
sensor.
Mechanically adjust top of angle sensor
housing exact parallel with boom by help of
inclinometer.
Fix adjustment screws of the angle sensor.
Having adjusted the angle sensor mechanically check value and press "OK" for the next step.
Calibration for "zero degree" angle:
leave the service menu
calibrate next angle
skip calibration step / go to next menu
Now boom up to 40°, (range is 35°- 45°)
Calibration for "40°" angle:
leave the service menu
calibrate next angle
skip calibration step / go to next menu
angle
sensor