Sensor Calibration
© 2009 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · eMail: info.ecs@hirschmann.de · www.hirschmann.com 16
24 183 69 1012e (Generic) / 2009-02-26 / Rev. 01 / rk.
When the boom angle is within the calibration range, the screen will add the
‘CHANGE ?’ / ‘SET’ and ‘OK’ text as shown below:
Calibration for "40°" angle:
leave the service menu
adjust actual angle
set current angle to defined angle
Measure the boom angle with the inclinometer and when the boom is positioned in the calibration
range, compare the measured angle to the displayed angle.
If the indicated angle is within +/- 0.1 degrees of the measured angle, confirm with ‘OK’.
Otherwise, select ‘SET’ to adjust the angle.
Adjust "40°" angle:
leave the service menu
increase angle value by 0.1°
Confirm
decrease angle value by 0.1°
Once you push ‘SET’ , the screen is going to change to the angle adjustment screen. Use the ‘+’
and ‘-‘ buttons to adjust the indicated angle to match the measured angle.
When the display shows the correct angle, press ‘OK’.
Press ESC to leave sensor adjustments and return to normal LMI screen.
Now repeat procedure as shown for the boom angle 65° and 75°.
If values were modified a confirmation screen appears at the end: