Redundancy
86
6.1
Ring Redundancy
RM Web L2B
Release
5.3
05/2012
6.1.1 Configuring the HIPER-Ring
For the ring ports, select the following basic settings in the Basic
Settings:Port Configuration dialog:
Note: Configure all the devices of the HIPER-Ring individually. Before you
connect the redundant line, you must complete the configuration of all the
devices of the HIPER-Ring. You thus avoid loops during the configuration
phase.
Port type Bit rate Autonegotiation
(automatic
configuration)
Port setting Duplex
TX 100 Mbit/s off on 100 Mbit/s full duplex (FDX)
Optical 100 Mbit/s off on 100 Mbit/s full duplex (FDX)
Table 21: Port settings for ring ports