18
Installation OCTOPUS OS3
Release
01
02/2019
Status Device Status none Device is starting and/or is not ready for
operation.
green lights up Device is ready for operation.
Characteristics can be configured
red lights up Device is ready for operation.
Device has detected at least one error in the
monitoring results
flashes 1 time
a period
The boot parameters used when the device
has been started differ from the boot
parameters saved.
Start the device again.
flashes 4 times
a period
Device has detected a multiple IP address
RM Ring Manager none No redundancy configured
green lights up Redundancy exists
flashes 1 time
a period
Device is reporting an incorrect
configuration of the RM function
yellow lights up No redundancy exists
ACA Storage medium
ACA
none ACA storage medium not connected
green lights up ACA storage medium connected
flashes 3 times
a period
Device writes to/reads from the storage
medium
yellow lights up ACA storage medium inoperative
LED Display Color Activity Meaning
Table 3: Device Status