7.5 Climatic conditions during operation
7.6 Climatic conditions during storage
Climatic conditions during operation
Minimum clearance around the device Top and bottom device side: 3.94 in (10 cm)
Ambient air temperature
a
a. Temperature of the ambient air at a distance of 2 in (5 cm) from the device
Standard -40 °F ... +140 °F
(-40 °C ... +60 °C)
Extended -40 °F ... +158 °F
(-40 °C ... +70 °C)
Humidity (also in condensing
atmospheres)
10 % ... 95 %
Air pressure min. 700 hPa
(+9842 ft; +3000 m)
max. 1060 hPa
(-1312 ft; -400 m)
Table 9: Climatic conditions during operation
Climatic conditions during storage
Ambient air temperature
a
a. Temperature of the ambient air at a distance of 2 in (5 cm) from the device
Standard -40 °F ... +185 °F
(-40 °C ... +85 °C)
Extended -40 °F ... +185 °F
(-40 °C ... +85 °C)
Humidity (also in condensing
atmospheres)
10 % ... 95 %
Air pressure min. 600 hPa
(+13123 ft; +4000 m)
max. 1060 hPa
(-1312 ft; -400 m)
Table 10: Climatic conditions during storage