66
Installation RS20/22/30/32/40
Release
05
12/2015
Environment Storage temperature
(ambient air)
Standard: 40 °F ... +158 °F
(40 °C ... +70 °C )
Extended 40 °F ... +185 °F
(40 °C ... +85 °C)
Humidity 10 % ... 95 %
(non-condensing)
Air pressure Up to 2000 m (795 hPa), higher
altitudes on request
Minimum clearance around the
device
Top and bottom device side: 3.94 in
(10 cm)
Left and right device side: 0.79 in
(2 cm)
Operating
temperature
a
RS20/RS30/RS40 Standard: +32 °F ... +140 °F
(0 °C ... +60 °C)
Extended 40 °F ... +158 °F
(40 °C ... +70 °C )
RS22-..., RS32-... Standard: 0 °C ... +60 °C
b)
Extended: 40 °F ... +140 °F
(40 °C to +60 °C)
c)
RS40-...B... (ATEX/IECEx)
Standard (S)
Temperature code T4:
+32 °F ... +140 °F (0 °C ... +60 °C)
RS40-...B... (ATEX/IECEx)
Extended (E and T)
Temperature code T3:
40 °F ... +158 °F
(40 °C ... +70 °C)
Temperature code T4:
40 °F ... +140 °F
(40 °C ... +60 °C)
RPS90/48V HV 40 °F ... +158 °F
(40 °C ... +70 °C)
Cold start at temperatures > 30 °C
RPS90/48V LV 40 °F ... +158 °F (40 °C ...
+70 °C)
Cold start at temperatures > 30 °C
at an input voltage 21.6 V DC
Pollution degree 2
Protection classes Laser protection Class 1 in compliance with IEC
60825-1
Degree of protection IP20
a. Exclusively use SFP modules with the “EEC” extension at temperatures > 60 °C and < 0 °C.
b. With a UL-508, ATEX/IECEx, or ISA 12.12.01 approval, the maximum operating
temperature for the standard ‘S’ temperature range for PoE-capable devices (RS22-...,
RS32-...) is +122 °F (+50 °C).
c. With a UL-508, ATEX/IECEx, or ISA 12.12.01 approval, the maximum operating
temperature for the extended ‘E’ and ‘T’ temperature range for PoE-capable devices (RS22-
..., RS32-...) is +122 °F (+50 °C).

Related product manuals