Loading...
Diagnostics
116
7.6
Signal contact
RM Web L2B
Release
5.3
05/2012
Note: If the device is a normal ring member and not a ring manager, it
doesn't report anything for the HIPER-Ring; for the MRP it only reports
detected errors in the local configuration.
7.6.3 Device status
Select the tab page “Alarm 1” or “Alarm 2” (for devices with two signal
contacts).
In the “Mode Signal Contact” field, you select the “Device status” mode.
In this mode, the signal contact monitors the device status (see on
page 111 “Device Status”) and thereby offers remote diagnosis.
The device status “Error detected” (see on page 111 “Device Status”) is
reported by means of a break in the contact via the potential-free signal
contact (relay contact, closed circuit).