Basic Settings
RM Web L2B
Release
5.3
05/2012
1.6
Loading/Saving the Configuration
37
a
In these cases, the ACA status is identical to the status “ACA not in
sync”, which sends “Not OK” to the signal contacts and the device status.,
b
In this case, the ACA status (“notInSync”) deviates from the status “ACA
not in sync”, which sends “OK” to the signal contacts, and the device
status.
Status Meaning
notPresent No ACA present
ok The configuration data from the ACA and the device match.
removed The ACA was removed after booting.
notInSync - The configuration data of the ACA and the device do not
match, or only one file exists
a
,
or
- no configuration file is present on the ACA or on the device
b
.
outOfMemory The local configuration data is too extensive to be stored on
the ACA.
wrongMachine The configuration data in the ACA originates from a different
device type and cannot be read or converted.
checksumErr The configuration data is damaged.
Table 3: ACA status