4.3 Error display
4.3.1 Error Code
Code
Problem
E0
Environment sensor malfunctions
E1
Refrigerator sensor malfunctions
E3
Freezer sensor malfunctions
E4
Freezer defrost sensor malfunctions
E8
Humidity Sensor malfunctions
Er
Communication receiving malfunctions
Ec
Communication sending malfunctions
F1
Freezer fan malfunctions
F0
Condenser fan malfunctions
LED
Item
Trouble
contents
Diagnostic
method
Detection
value
image
E0
E-Sensor Error
Display error :
separation of
sensor housing
part, contact
error,
disconnection,
short circuit.
Display error
of detecting
temperature of
sensor :
more than 65°
C or less than
-50°C
Measuring
the voltage
between the
Main PCB
CN1 2PIN and
4PIN
4.5V~1.0V
E1
R-Sensor Error
Measuring
the voltage
between the
Main PCB
CN1 9PIN
and 10PIN
E3
F-Sensor Error
Measuring
the voltage
between the
Main PCB
CN1 6PIN
and 7PIN
E4
F-DEF-Sensor
Error
Measuring
the voltage
between the
Main PCB
CN1 5PIN and
7PIN

Table of Contents