7. Cooling system repairing
7.1 Refrigeration system
Compressor discharges high temperature
high pressure R600a gas refrigerant
Refrigerant enters anti-condensation pipe
condenser, then becomes middle temperature
high pressure liquid after condensation
Refrigerant enters dry filter,water and imperity will
be filtrated
Refrigerant enters Electromagnetism valve, and
Capillary, then pressure will be reduced
Refrigearnt enters finned evaporator and
become low temperature low pressure gas after
absorbing heat from freezer and refrigerator
compartment