34
22” TFT TV Service Manual
Nicam Prs Avl On
Adjusts the Nicam Prescaler value, when Automatic Volume Levelling is On
Min. Value: 0000 00000
Max. Value: 00FF 00255
Recommended Value: 0027 00039: for 16 ohm
Scart Prs Avl On
Adjusts the Scart Prescaler value, when Automatic Volume Levelling is On
Min. Value: 0000 00000
Max. Value: 00FF 00255
Recommended Value: 0010 00016: for 16 ohm
Scart Volume Avl On
Adjusts the Scart Volume value, when Automatic Volume Levelling is On
Min. Value: 0000 00000
Max. Value: 00FF 00255
Recommended Value: 003E 00062: for 16 ohm
FM Prs Avl Off
Adjusts the FM Prescaler value, when Automatic Volume Levelling is Off
Min. Value: 0000 00000
Max. Value: 00FF 00255
Recommended Value: 000C 00012: for 16 ohm
Nicam Prs Avl Off
Adjusts the Nicam Prescaler value, when Automatic Volume Levelling is Off
Min. Value: 0000 00000
Max. Value: 00FF 00255
Recommended Value: 001C 00028: for 16 ohm
Scart Prs Avl Off
Adjusts the Scart Prescaler value, when Automatic Volume Levelling is Off
Min. Value: 0000 00000
Max. Value: 00FF 00255
Recommended Value: 000C 00012: for 16 ohm
Scart Volume Avl Off
Adjusts the Scart Volume value, when Automatic Volume Levelling is Off
Min. Value: 0000 00000
Max. Value: 00FF 00255
Recommended Value: 003E 00062: for 16 ohm
X
Not used
Options...
X
X
X
Avl
Top TXT
Fast TXT
TXT Lang
IF Freq
Sound
Carrier
036: On