5. Test Run
A16381TMF2
15
No. Item Optional Function
Individual
Setting
Setting
Condition
Contents Setting
96 L1 Setting Position of Motion Sensor -
00
01
02
03
A
B
--
D
97 L2 Not used -
00
01
00
01
98 L3
Select louver operation in energy-
saving Th.-OFF (COOL & DRY)(*12)
○
00
01
02
Low air ow
Medium air ow
High air ow
99 L4
Fan Speed during Energy-Saving
Forced Thermo-OFF
○
00
01
Usual setting
Available
100 L5
Louver Swing Operation Energy-
Saving Forced Thermo-OFF
○
00
01
Unavailable
Available
101 L6 Not used -
00
01
00
01
102 L7 Not used - - Not Used (Use as 00 setting conditions)
103 L8 Not used -
00
01
00
01
104 L9
Auxiliary Heater at Defrosting
Operation
-
00
01
Unavailable
Available
105 LA Humidier blow control On/O -
00
01
Unavailable
Available
106 Lb
Humidier blow control time
setting
-
00
01
4hours ON 30min OFF
30min ON 10min OFF
107 P1 Setting temperature ×
00
01
0.5
o
C steps
1
o
C steps
108 P2 Not used -
00
01
00
01
109 P3 Select temperature sensor(*13) ×
00
01
02
03
Inlet Air Thermistor
Outlet Air Thermistor
Thermistor of Wired Controller
Remote Sensor
110 P4 Temperature sensor display(*14) ×
00
01
Unavailable
Available
111 P5
Temperature setting display in fan
mode
×
00
01
Show
Hide
112 P6 Not used -
00
01
00
01
113 P7 Menu screen transition prohibited ×
00
01
Unavailable
Available
114 P8 Maintenance explanation display ×
00
01
Available
Unavailable
115 P9 Alarm explanation display ×
00
01
Available
Unavailable
116 PA Daylight Savings Time ×
00
01
00
01
117 Pb Not used -
00
01
00
01
118 PC Not used -
00
01
00
01
119 q1 Auxiliary Heater Setting ×
00
01
Unavailable
Available
120 q2 Auxiliary Heater ON Compensation ×
00
01
02
03
04
05
06
07
08
09
-1.5°C (-3°F)
-2.0°C (-3°F)
-2.5°C (-4°F)
-3.0°C (-5°F)
-3.5°C (-6°F)
-4.0°C (-7°F)
-4.5°C (-8°F)
-5.0°C (-9°F)
-0.5°C (-1°F)
-1.0°C (-2°F)
121 q3 Auxiliary Heater OFF Compensation ×
00
01
0.0°C (0°F)
0.5°C (1°F)