“B” Group Parameters Default Setting
Func.
Code
Name
-FE
(EU)
-FU
(USA)
B031
=10
User
Setting
B080 [AM]analog signal gain 100. 100.
9
B082 Start frequency adjustment 0.5 0.5
9
B083 Carrier frequency setting 3.0 3.0
U
B084 Initialization mode (parameters or trip
history)
00 00
U
B085 Country for initialization 01 02
U
B086 Frequency scaling conversion factor 1.0 1.0
9
B087 STOP key enable 00 00
9
B088 Restart mode after FRS 00 00
9
B089 Monitor display select for networked
inverter
01 01
9
B091 Stop mode selection 00 00
U
B092 Cooling fan control 00 00
U
B130 Over-voltage LADSTOP enable 00 00
9
B131 Over-voltage LADSTOP level 380 / 760 380 / 760
9
B133 DC bus AVR selection 00 00
9
B134 Threshold voltage of DC bus AVR
setting
380/760 380/760
9
B140 Over-current trip suppression 00 00
9
B150 Carrier mode 00 00
9
B151 Selection of RDY function 00 00
9
C7