32
Displaying the condition of the projector (continued)
• While the projector is searching an input signal in normal condition, 
nothing is displayed on the 2nd line of the monitor.
• Displayed temperature might differ from actual peripheral temperature 
because the displayed temperature is measured inside of the projector.
NOTE
Status Monitor 
 In error state 
The Status Monitor displays a warning of an error with 
larger letters. Resolve the errors referring to the table 
of the sections "Related messages" (
114 ~ 116) and 
"Regarding the indicator lamps" (117 ~ 121) when the 
warning is displayed.
Warnings;
AIR (AIR FLOW): The internal temperature is rising.  
Refer to the description of the message, "CHECK THE AIR FLOW" in the 
table (
115).
COLD: There is a possibility that the interior portion has become over cooled. 
Refer to the LAMP and TEMP indicators alternatively blinking in the table 
(
120).
FILTR (FILTER): It is time to clean the air lter.  
Refer to the LAMP and TEMP indicators simultaneous blinking in the table 
(
120).
SHADE: Shade Error 
Contact your dealer or service company.
SHIFT: Lens Shift Error 
Contact your dealer or service company.
Errors;
COVER: The lamp cover has not been properly xed. 
Refer to the LAMP indicator blinking in the table (
118).
FAN: The cooling fan is not operating. 
Refer to the TEMP indicator blinking in the table (
118).
LAMP: The lamp does not light. 
Refer to the LAMP indicator lighting in the table (
118).
TEMP: The projector's interior becomes over heated. 
Refer to the TEMP indicator lighting in the table (
119).
ACBLK: Refer to the LAMP indicator lighting in the table (
118).
OTHER: Errors other than the above (
119).
• When one of the warnings of FAN, LAMP, COVER, TEMP errors is 
displayed, the backlight blinks at the same time.
NOTE
example
O RC EV