6-5 Air filter
The air lter unit of this projector consists of a lter cover, two kinds of lters, and
a lter frame. The new double large lters system is expected to function longer.
However, please check and clean it periodically to keep ventilation needed for
normal operation of the projector.
When the indicators or a message prompts you to clean the air lter, comply with
it as soon as possible. Replace the lters when they are damaged or too soiled.
Cleaning and replacing the air lter
1.
Turn the projector off, and unplug the power cord.
Allow the projector to sufciently cool down.
2.
Use a vacuum cleaner on and around the lter cover.
3.
Pick and pull up the lter cover knobs to take it off.
4.
Use a vacuum cleaner for the lter vent of the
projector.
5.
Take the ne meshed lter out while holding the
lter cover. It is recommended to leave the coarse
meshed lter in the lter cover as it is.
7.
Put the ne meshed lter on the coarse meshed
one, turning its stitched side up.
8.
Put the lter unit back into the projector.
When you replace the lamp, please replace the air lter. An air lter of specied
type will come together with a replacement lamp for this projector.
Stitched
side
6.
Use a vacuum cleaner on both sides of the ne
meshed lter while holding it so it will not be
sucked in. Use a vacuum cleaner for the inside of
the lter cover to clean up the coarse meshed lter.
If the lters are damaged or heavily soiled, replace
them with new ones.
Filter (ne meshed)
Filter (coarse meshed)
Intake vent
Filter cover
Filter cover knobs
2
7
4
3
9.
Turn the projector on and reset the lter time using the FILTER TIME item in
the EASY MENU.
Before taking care of the air lter, make sure the power cable
is not plugged in, then allow the projector to cool sufciently. Taking care of the
air lter in a high temperature state of the projector could cause an electric shock,
a burn or malfunction to the projector.
Use only the air lter of the specied type. Do not use the projector without the
air lter or the lter cover. It could result in a re or malfunction to the projector.
Clean the air lter periodically. If the air lter becomes clogged by dust or the
like, internal temperatures rise and could cause a re, a burn or malfunction to
the projector.
WARNING
• Please replace the air lter when it is damaged or too soiled.
• When you replace the projection lamp, please replace the air lter. An air lter
of specied type will come together with a replacement lamp for this projector.
• Please reset the lter time only when you have cleaned or replaced the air
lter, for a suitable indication about the air lter.
• The projector may display the message such as “CHECK THE AIR FLOW” or
turn off the projector, to prevent the internal heat level rising.
NOTE
(1) Press the MENU button to display a menu.
(2) Point at the FILTER TIME using the / button, then press the button.
A dialog will appear.
(3) Press the button to select “OK” on the dialog. It performs resetting the
lter time.