i
MN1-6013 Rev.4
L44LA Probe
Instruction Manual
Specication
MN1- 6013 Rev.4
Notes for operators and responsible maintenance personnel
★
Please read through this Instruction Manual as well as the separate Instruction
Manual “Safety (MN1-5984)” and “Cleaning, Disinfection and Sterilization
(MN1-6000)“ carefully prior to use.
★
Keep this Instruction Manual together with the ultrasound diagnostic instru-
ment for any future reference.
© Hitachi, Ltd. 2014, 2017. All rights reserved.
Question and Answer IconNeed help?

Do you have a question about the Hitachi L44LA and is the answer not in the manual?

Hitachi L44LA Specifications

General IconGeneral
BrandHitachi
ModelL44LA
CategoryMeasuring Instruments
LanguageEnglish

Summary

General Information

Intended use

Specifies the intended medical use of the L44LA probe for intraoperative diagnosis via trocar.

Classification of ME equipment

Details the probe's classification per IEC60601-1, covering protection against electric shock and liquid ingress.

Standard components

Lists the standard items included with the L44LA probe, such as the probe, protect tube, and associated manuals.

Options

Confirms that no optional accessories or components are available for the L44LA probe.

Specifications and Parts name

Specifications

Provides key technical specifications including application, patient contact type, connectable instruments, frequency, and cable length.

Name of each parts

Identifies and explains the function of each physical component of the L44LA probe.

Specifications of the protect tube

Details the material, compatible trocar size, service life, and external dimensions of the protect tube.

Preparations for Use

Visual check

Instructs on visually inspecting the probe for any damage, cracks, or abnormalities before operation.

Deflection portion operation check

Guides on checking the smooth, unrestricted operation of the probe's deflection levers and tip.

Confirmation of cleaning and sterilization

Emphasizes confirming that the probe has been properly cleaned and sterilized as per guidelines.

Verification of operation

Details connecting the probe to the ultrasound instrument and verifying correct scan type, frequency, and image output.

Torocar connection check

Ensures the protect tube is correctly and smoothly attached to the trocar outer sheath.

Probe insertion check

Confirms the probe can be smoothly inserted into and removed from the protect tube.

Operation

Preparations of the protect tube

Describes attaching the protective cap to the protect tube as a preparatory step before probe insertion.

Insertion of the probe

Details inserting the probe into the trocar outer sheath, securing it, and adjusting the deflection.

Operation

Explains how to position the probe on the organ surface and utilize the ultrasound instrument's display.

Pulling out the probe

Guides on safely straightening, pulling out the probe, and subsequent cleaning and sterilization.