HITACHI F-4700 FLUORESCENCE SPECTROPHOTOMETER (MAINTENANCE MANUAL)
INSTRUCTION MANUAL
5J2-9015-000 Ver.1 September. 2017
Fluorescence Spectrophotometer
HITACHI F-4700
FLUORESCENCE
SPECTROPHOTOMETER
(MAINTENANCE
MANUAL)

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Hitachi F-4700 and is the answer not in the manual?

Hitachi F-4700 Specifications

General IconGeneral
TypeFluorescence Spectrophotometer
ModelF-4700
Excitation Light Source150 W Xenon lamp
DetectorPhotomultiplier tube
Wavelength Range (Emission)200 - 900 nm
Spectral Bandwidth5, 10, 20 nm
Scan Speed12000 nm/min
Data OutputRS-232C
Data Sampling Interval0.1, 0.2, 0.5, 1, 2, 5 nm
Weight60 kg
Optical SystemSingle monochromator for both excitation and emission

Summary

FOREWORD

PREFACE

ABOUT THIS MANUAL

IMPORTANT INFORMATION

User Information and Disposal

Information on WEEE compliance and product disposal procedures for users.

Product Warranty Details

Outlines the warranty scope, period, and limitations for the F-4700 spectrophotometer.

Instrument Service Life

Specifies the estimated useful service life of the instrument and safety checks.

Installation, Relocation, and After-sales Service

Details procedures for installation, relocation, and obtaining after-sales technical support.

User Training and Other Precautions

Covers training courses, handling of chemicals, samples, and trademark acknowledgments.

SAFETY SUMMARY

General Safety Precautions

Provides essential safety instructions and guidelines to be followed before operating the instrument.

Detailed Safety Guidelines

Further safety guidelines covering operation, modifications, and chemical handling.

Hazard Warning Indications

Explains the meaning of DANGER, WARNING, and CAUTION symbols and their implications.

Warning Labels Explained

Illustrates and describes the warning labels attached to the F-4700 fluorescence spectrophotometer.

1. INSTALLATION

1.1 Installation Requirements

Specifies the necessary conditions and space for installing the F-4700 spectrophotometer.

1.1.2 Environment Requirements

Details operating and storage conditions including temperature, humidity, and ambient gas.

1.1.3 Power Requirement

Outlines the electrical specifications for power supply voltage, frequency, capacity, and grounding.

1.2 Unpacking and Delivery Check

Instructions for safely unpacking the instrument and verifying delivered items.

1.4 Power Voltage and Fuse Check

Guide for checking the power supply voltage and fuse capacity before connecting the instrument.

1.5 Assembly Procedures

Step-by-step instructions for assembling the F-4700 spectrophotometer, including Xenon lamp attachment.

1.6 FL Solutions Program Installation

Procedure for installing the FL Solutions program on a Windows 10 PC, including driver setup.

1.7 Startup of FL Solutions Program

Instructions for starting up the FL Solutions program and initializing the spectrophotometer.

1.10 Light Source Position Adjustment

Procedures for adjusting the position of the light source for optimal performance.

1.11 Performance Check

Guidance on checking the instrument's performance parameters after installation.

2. FUNCTIONS

2.1 Instrument Configuration

Overview of the F-4700 spectrophotometer's main components and their arrangement.

2.2 Component Identification

Description and function of each major component of the spectrophotometer main unit.

2.3 Operating Principle

Explanation of the instrument's signal processing, control system, and optical path.

2.4 Measurement Functions

Details on available measurement modes and automatic calibration/self-diagnosis features.

2.5 Specifications

Lists the technical specifications and performance characteristics of the F-4700.

3. MAINTENANCE AND INSPECTION

3.1 Light Source Positional Adjustment

Procedures for visually adjusting the Xe lamp position for optimal light output.

3.2 Performance Checks

Instructions for verifying instrument performance, including wavelength accuracy and sensitivity.

3.3 Xe Lamp Usage Time

How to monitor and manage the cumulative usage time of the Xe lamp for maintenance.

3.4 Lens Cleaning

Steps for cleaning the excitation and emission side lenses in the sample compartment.

3.5 Cell Holder Cleaning

Procedures for cleaning the cell holder and base if sample spillage occurs.

3.6 Troubleshooting Guide

Common symptoms, causes, judgment methods, and remedies for instrument issues.

4. REPLACEMENT PARTS

4.1 Consumables and Spare Parts

Lists consumable and spare parts recommended for maintaining the spectrophotometer.

4.2 Limited-Life Parts

Identifies parts with a limited lifespan and their replacement standards.

4.3 Xenon Lamp Replacement

Detailed instructions and safety precautions for replacing the xenon lamp.

4.4 Xenon Lamp Disposal

Guidance on the safe and proper disposal procedures for used xenon lamps.

4.5 Power Fuse Replacement

Steps for replacing a blown power fuse, including safety warnings.