MN1-5821 Rev. 4
C25P Probe
Instruction Manual
Specication
MN1-5821 Rev. 4
Notes for operators and responsible maintenance personnel
★
Please read through this Instruction Manual as well as the separate Instruction
Manual “Safety (MN1-5982)” and “Cleaning, Disinfection and Sterilization
(MN1-5998)“ carefully prior to use.
★
Keep this Instruction Manual together with the ultrasound diagnostic instrument
for any future reference.
© Hitachi, Ltd. 2014, 2017. All rights reserved.
Q1E-EP1473-4
Question and Answer IconNeed help?

Do you have a question about the Hitachi C25P and is the answer not in the manual?

Hitachi C25P Specifications

General IconGeneral
BrandHitachi
ModelC25P
CategoryMeasuring Instruments
LanguageEnglish

Summary

Introduction and Safety Symbols

Safety Symbols Defined

Explains safety symbols like Danger, Warning, Caution, and Note, along with their meanings and corresponding icons.

General Information

Intended Use and Application

Specifies the intended users and primary use of the probe for abdominal organ observation and puncture.

ME Equipment Classification

Details the probe's classification according to IEC60601-1 regarding electric shock and liquid ingress.

Standard Components List

Lists the standard items included with the C25P probe, such as the probe, case, and manuals.

Optional Accessories

Describes optional accessories for the C25P probe, including biopsy attachments and Real Time Virtual Sonography (RVS).

Specifications and Parts

Technical Specifications

Lists technical specifications like application, connectable instruments, frequency, cable length, and service life.

Probe and Biopsy Attachment Identification

Identifies and illustrates the probe components and optional biopsy attachment parts using diagrams.

Preparations Before Use

Probe Preparation Steps

Outlines essential steps for preparing the probe, including visual checks and cleaning confirmation.

Visual Probe Check

Instructs users to visually inspect the probe tip, cable, and connector for any damage or abnormalities.

Cleaning and Sterilization Verification

Emphasizes verifying the probe and accessories are properly cleaned, disinfected, and sterilized before use.

Operation Check Procedure

Details how to connect the probe and verify correct scan type, frequency, and image output.

Required Probe Cover

Specifies the required probe cover for use with the C25P probe.

Biopsy Attachment Preparation

Provides instructions for inspecting and confirming the readiness of the biopsy attachment.

Biopsy Attachment Inspection

Guides users to visually check the biopsy attachment for damage before use.

Needle Echo Confirmation Procedure

Explains the procedure to confirm the needle echo and its alignment with the puncture guideline.

Operation

Attaching Probe Cover to Probe

Details the initial steps for applying a probe cover to the probe tip and securing it with a rubber band.

Assembling and Attaching Biopsy Attachment

Describes assembling the biopsy attachment components and attaching it to the probe via mounting arms.

Securing Biopsy Attachment

Details the final steps for securing the biopsy attachment to the mounting plate and arm, ensuring proper fit.

Confirming Needle Path and Attachment Fit

Explains how to confirm the needle path compatibility and the correct attachment of the biopsy device.

Probe Operation and Puncture Guidance

Describes general operation, probe placement, and performing a puncture with insertion angle guidance.

Probe Release and Safety Warnings

Provides instructions for releasing the probe from the biopsy attachment and lists critical safety warnings.

Magnetic Position Sensor Attachment;Release

Details the procedure for attaching and detaching the magnetic position sensor and its attachment.