Chapter 2 Specifications
2 – 8
2.7 Output specifications
(1) Relay output (All output on MV-*64DR, MV-*40DR, MV-*20DR)
5 to 250V AC, 5 to 30V DC
Minimum switching current
64-point type: 24
40-point type: 16
20-point type: 8
64-point type: 9
40-point type: 5
20-point type: 2
Removable type screw terminal block (M3)
Externally supplied power
(for driving the relays)
20,000,000 times (mechanical)
200,000 times (electrical: 1.5A)
1,500V or more (external-internal)
500V or more (external-external)
*1: Minimum switching current is the unofficial value as a guide. This value may vary with the switching frequency,
environmental conditions, etc..
*2: Refer the diagram below
■ Life of relay contact
Life curve of relay contact
Switching life (10,000 times)
Life of the contact is also in squared reverse proportion to the
current, so be aware that interrupting rush current or directly driving
the capacitor load will drastically reduce the life of the relay.