◆ Example 3
1 Move Unit controller to the living room (use as Unit controller + Room Thermostat)
2 Wired unit controller as a Room Thermostat for Zone 1
3 Wired room sensor for Zone 2
OK
Outdoor unit
Indoor unit
1
Living room Zone 1
Bedroom Zone 2
Order FIRST
Type
Master
Unit + Circuits
Quesons Answers
Is this device aached to the unit? NO
Is this device controlling the unit? YES
Is this device used as a Room Thermostat of a zone? YES, IN BOTH ZONES
Which are the emiers of circuit 1? Underoor heang
Which are the emiers of circuit 2? Underoor heang
Do you have domesc hot water tank? NO
Do you have swimming pool? NO
Do you have boiler? NO
Do you have electric backup heater? NO
COMPLETED
NOTE
• Aer nishing Conguraon assistant, go to Input&Outputs&Sensor menu and select which
auxiliary sensor do you want to use for ambient temperature in Zone 2.
• Example: Sensor 1 : C2 Ambient