PC-ARFH1E FUNCTIONALITIES
In this manner, given two idencal rooms, the YUTAKI unit determines the same room temperature
according to OTC control. On the other hand, for a room in which there is a wider dierence
between seng temperature and actual temperature, the YUTAKI unit will increase the
temperature of the pumped water in order to ensure a similar heang up me unl reaching the
seng temperature.
Compensaon has no eect if Compensaon factor is 0 or when OTC is Fix, and water temperature
is determined according to OTC in chapter Water calculaon mode” in such case.
The more the factor is increased, the more is water temperature increased by the YUTAKI unit
according to the dierence between seng temperature and the current temperature.
Maximum compensaon factor heat + and - : Maximum dierence between room temperature
and seng temperature. In case that the dierence between room temperature and seng
temperature is higher than this value, the YUTAKI unit takes the selected value as the maximum.
1.8.2.2 Timer and schedule conguraon
NOTE
Timer sengs are only valid if the corresponding zone is in ON state at the me of execuon of the
respecve mer program.
The LCD controller must be set to the correct date and me before using the mer funcon.
Select the desired area to apply the mer funcon or delete all mers conguraon:
Heang/Cooling (Air): To set the mer to
adjust the room temperature. Only when
using room thermostats.
Heang/Cooling (Water): To set the mer
to adjust the water working condions.