32
PMEN0602 rev.0 - 05/2023
1
MAIN SCREEN
PC-ARFH1E FUNCTIONALITIES
1.7.2 Comprehensive view
Time and date
The current me/date informaon is displayed. This informaon can be changed on the
conguraon menu.
Operaon mode (Heang/Cooling/Auto)
This icon shows the unit’s mode of operaon status. It has to be edited by pressing the OK buon,
and it can be switched between Heang, Cooling and Auto mode. (If available opon).
Control of circuits 1 and 2
It displays the seng temperature calculated for each circuit and a throughput icon indicang the
percentage of the actual temperature with respect to the seng temperature. It can also show
the ECO mode and mer acvaon if they are enabled.
The seng temperature can be modied using the arrows keys over this view (if water calculaon
mode is set as x).
Pressing the OK buon, the following quick acons are shown:
✓ Timer: In this menu, simple mer or schedule mer can be selected and congured.
✓ OTC: OTC Seng temperature (User can only refer to the OTC mode and its seng
temperature value)
✓ ECO/Comfort: Selecon between ECO and Comfort mode.
✓ Status: Some working condions can be consulted.
DHW control
It displays the seng temperature for DHW and a throughput icon indicang the percentage of
the actual temperature with respect to the seng temperature. It can also show the operaon of
the electrical heater of the DHW, the mer acvaon and the DHW boost if they are enabled.