Loading...
How to set prevention of mutual interference for remote controller
[ Remote controller model : RAR-6NE2 ]
In this case : 2 sets indoor units are installed near to each other.
If both indoor unit can receive a remote controller signal, please set as below.
( This setting change the signal addres of remote controller.)
Initial setting is A
This flow change the signal address form A to B.
Signal transmission : From A to B
Signal transmission : From B to A
The power breaker for other unit shallbe OFF.
Open the slide cover of remote controller.
Direct remote controller towards the receiver of changing indoor unit and press [RESET] button
while pressing [1-6] button and [ON] button. ---> Transmission
Notes : If indoor unit didnot receive the signal, setting shall be made
When the indoor unit receive the signalfrom remote controller, beep sound [Pip]will emit.
Please check to be used the remote controller.
one more time.
Once again setting, the signal address changes from B to A.
If once more again setting, the signal address change from A to B.
Please set the DIP switch No.6 to ON accordingly (Refe to page *
73*).