– 45 –
Table 1 Mode data le
LABEL NAME VALUE
WMAX
WMAX2 5200 min
–1
WSTD 4750 min
–1
WBEMAX 3600 min
–1
CMAX 5000 min
–1
CSTD 4600 min
–1
CKYMAX 3900 min
–1
CJKMAX 3900 min
–1
CBEMAX 2300 min
–1
WMIN 1200 min
–1
CMIN 1600 min
–1
STARTMC 60 Seconds
DWNRATEW 100%
DWNRATEC 100%
SHIFTW 0.00°C
SHIFTC 1.00°C
CLMXTP 30.00°C
YNEOF 25.00°C
TEION 2.00°C
TEIOF 9.00°C
SFTDSW 0.66°C
DFTIM1 50 Minutes
DFTIM2 60 Minutes
RAS-24MH1
5200 min
–1