3.2.4.3 YUTAKI S80
Version for indoor unit alone
RWH-(4.0-6.0)(V)NFE
Model Power supply
Applicable voltage
Operation mode
RNC
(A)
IPT
(kW)
MC
(A)
Max.
IPT
(kW)
U max.
(V)
U min.
(V)
RWH-4.0VNFE
1~ 230V 50Hz 253 207
Without simultaneous operation of electric heater
in DHW tank
12.1 2.73 24 5.33
With simultaneous operation of electric heater in
DHW tank
25.4 5.73 38 8.33
RWH-5.0VNFE
Without simultaneous operation of electric heater
in DHW tank
12.3 2.78 28 6.23
With simultaneous operation of electric heater in
DHW tank
25.6 5.78 42 9.23
RWH-6.0VNFE
Without simultaneous operation of electric heater
in DHW tank
14.3 3.23 31 6.91
With simultaneous operation of electric heater in
DHW tank
27.6 6.23 45 9.91
RWH-4.0NFE
3N~ 400V 50Hz 440 360
Without simultaneous operation of electric heater
in DHW tank
5.6 2.73 10 4.68
With simultaneous operation of electric heater in
DHW tank
11.8 5.73 24 7.68
RWH-5.0NFE
Without simultaneous operation of electric heater
in DHW tank
5.7 2.78 10 4.68
With simultaneous operation of electric heater in
DHW tank
11.9 5.78 24 7.68
RWH-6.0NFE
Without simultaneous operation of electric heater
in DHW tank
6.7 3.23 10 4.68
With simultaneous operation of electric heater in
DHW tank
12.8 6.23 24 7.68
? NOTE
The data corresponding to DHW tank heater is calculated in combination with the YUTAKI S80 domestic hot water tank accessory
“DHWT-(200/300)S-3.0H2E”.