Type | Heat Pump |
---|---|
Cooling Capacity | 2.5 kW |
Power Supply | 220-240V, 50Hz |
Refrigerant | R410A |
Indoor Unit Weight | 9 kg |
Provides general overview and notes about the YUTAKI system and documentation.
Explains the meaning of symbols used in the manual for safety and information.
Details the classification and listing of different YUTAKI units, including split and monobloc systems.
Provides crucial safety precautions and warnings for installation and operation of the heat pump.
Highlights critical instructions for manual adherence to ensure proper system function and prevent faults.
Outlines key considerations and terminology for understanding electrical specifications of the units.
Provides electrical specifications for R410A outdoor units used with YUTAKI S and S COMBI.
Presents electrical specifications for YUTAKI M (R32) and YUTAKI M (R410A) monobloc systems.
Details guidelines for water circuit design, including piping lengths and sizes for various YUTAKI models.
Defines the acceptable nominal, operating, and starting voltage ranges for power supply.
Illustrates the operational temperature ranges for R410A units in space heating mode.
Presents temperature working ranges for R32 units in space heating configurations.
Illustrates pump performance curves for YUTAKI S and S COMBI units.
Details refrigerant piping length requirements and minimum area considerations for YUTAKI S/S COMBI.
Outlines essential precautions and countermeasures for handling gas refrigerant leaks.
Details the required water piping connection sizes (inches) for different YUTAKI models and functions.
Ensures power supply installation conditions are met, including capacity, voltage, and impedance.
Outlines mandatory protection devices like Earth Leakage Breakers (ELB) and circuit breakers (CB).
Illustrates main power supply and communication wiring connections to terminal boards.
Describes connections for PC-ARFH1E, 4-20mA, Earth, and DHWT Thermistor.
Identifies and explains the function of each button on the PC-ARFH1E unit controller.
Guides through controller configuration steps, including language, date, time, and assistant setup.
Guides through configuring all system settings, including general options, timers, and water settings.
Explains configuration for DHW settings, including control modes, temperatures, and anti-legionella functions.
Provides steps for commissioning the system, including air purging, unit testing, and screed drying.
Identifies and explains the function of each button on the YUTAKI CASCADE CONTROLLER.
Guides through cascade controller configuration, including language, date/time, and assistant setup.
Guides through configuring system settings, including general options, timers, and cascade configuration.
Explains DHW settings, including control modes, temperatures, anti-legionella, and space priority.
Lists and explains alarms for indoor units, including their codes, details, and main factors.
Lists and explains alarms related to outdoor units, covering categories like Transmission and Power Supply.
Provides general procedures for inspection and maintenance of the unit, emphasizing safety precautions.
Details routine maintenance checks for the outdoor unit's fan, heat exchanger, piping, cabinet, and electrical components.
Outlines periodic checks for the indoor unit's cabinet, water piping, flow, ground wire, and electrical equipment.
Provides step-by-step instructions for draining the YUTAKI S, S COMBI, S80, and M indoor units and DHW circuits.