Safety summary & control device setting19
19  SAFETY SUMMARY & CONTROL DEVICE SETTING
 
Compressor Protection
High pressure switch:
This switch cuts out the operation  of the  compressor when  the 
discharge pressure exceeds the setting.
 
Fan Motor Protection
When the fan motor current is reached to the setting, motor output 
is decreased.
The other way, when the fan motor current becomes lower, limi-
tation is cancelled.
For compressor
  Pressure switches
   High
Cut-Out
Cut-In
MPa
Automatic reset, non-adjustable  
(each one for each compressor)
  -0.05
4.15
  -0.15
MPa 3.20 ± 0.15
For control
     Fuse
  1φ, 230V, 50Hz
A 25
      CCP timer
  Setting time min.
Non-Adjustable
3
For condenser fan motor
Internal thermostat
Cut-Out
Automatic reset, non-adjustable  
(each one for each motor)
ºC
-
For control circuit
Fuse capacity on PCB
A 3