EasyManua.ls Logo

Hitachi S1-00073HFE - Page 152

Hitachi S1-00073HFE
235 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
S1 series standard inverter
-147-
Function
code
Name
Detailed parameter description
Default
value
Modify
motor 2
P12.10
No-load current of
asynchronous
motor 2
0.16553.5A
Depend
on
model
P12.11
Magnetic
saturation
coefficient 1 of
iron core of
asynchronous
motor 2
0.0100.0%
80%
P12.12
Magnetic
saturation
coefficient 2 of
iron core of
asynchronous
motor 2
0.0100.0%
68%
P12.13
Magnetic
saturation
coefficient 3 of
iron core of
asynchronous
motor 2
0.0100.0%
57%
P12.14
Magnetic
saturation
coefficient 4 of
iron core of
asynchronous
motor 2
0.0100.0%
40%
P12.24
Reserved
00xFFFF
0x0000
P12.25
Reserved
0%50% (of the rated current of the motor)
10%
P12.26
Overload
protection of
motor 2
0: No protection
1: Common motor (with low-speed compensation)
2: Frequency-variable motor (without low-speed
compensation)
2
P12.27
Overload
protection
coefficient of
motor 2
Motor overload multiples M = Iout/(In×K)
In is rated motor current, lout is inverter output
current, K is motor overload protection coefficient.
The smaller the K, the larger the value of M, the
100.0%

Table of Contents