EasyManua.ls Logo

Hitachi S1-00073HFE - Page 73

Hitachi S1-00073HFE
235 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
S1 series standard inverter
-68-
Function
code
Name
Detailed parameter description
Default
value
P05.30
Corresponding setting of
lower limit of AI2
-100.0%100.0%
-100.0%
P05.31
Intermediate value 1 of AI2
P05.29P05.33
0.00V
P05.32
Corresponding setting of
intermediate value 1 of AI2
-100.0%100.0%
0.0%
P05.33
Intermediate value 2 of AI2
P05.31P05.35
0.00V
P05.34
Corresponding setting of
intermediate value 2 of AI2
-100.0%100.0%
0.0%
P05.35
Upper limit value of AI2
P05.3310.00V
10.00V
P05.36
Corresponding setting of
upper limit of AI2
-100.0%100.0%
100.0%
P05.37
Input filter time of AI2
0.000s10.000s
0.100s
P05.38
Lower limit of
AI3
-10.00VP05.39
-10.00V
P05.39
Corresponding setting of the
lower limit of AI3
-100.0%100.0%
-100.0%
P05.40
Middle value of AI3
P05.38P05.42
0.00V
P05.41
Corresponding middle
setting of AI3
-100.0%100.0%
0.0%
P05.42
Upper limit of AI3
P05.4010.00V
10.00V
P05.43
Corresponding setting of
the upper limit of AI3
-100.0%100.0%
100.0%
P05.44
AI3 input filter time
0.000s10.000s
0.100s
P05.45
Lower limit frequency of
HDI/HDIA
0.000 KHz P05.41
0.000KHz
P05.46
Corresponding setting of
lower limit frequency of
HDI/HDIA
-100.0%100.0%
0.0%
P05.47
Upper limit frequency of
HDI/HDIA
P05.39 50.000KHz
50.000KHz
P05.48
Corresponding setting of
upper limit frequency of
HDI/HDIA
-100.0%100.0%
100.0%
P05.49
HDI/HDIA frequency input
filter time
0.000s10.000s
0.030s
P05.50
Lower limit frequency of
HDIB
0.000 KHz P05.47
0.000KHz
P05.51
Corresponding setting of
lower limit frequency of HDIB
-100.0%100.0%
0.0%

Table of Contents

Related product manuals