2.8 Chopper Braking Resistor
SH1 Series has a built-in chopper braking circuit in model below.
SH1-00041-H (007H) to SH1-00930-H (370H)
• By using an optional braking resistor, permit to use for high
regeneration load application such as lift or high speed load.
■400V
When using regenerative resistor SRB series and RB series in
400V class, be sure to use two in series because of the
restriction of withstanding voltage of the resistor.
Example: In the case of RB2 × 2 series × 2 parallel,
a total of 4 RB2s are required.
• SH1 Series can offer when desired a built-in chopper braking circuit
in models below.
SH1-01160-H (450H) to SH1-01470-H (550H)
• Using optional braking unit or regenerative unit, permit to use on
high regenerative load application even for models without built-in
chopper braking circuit.
• The table below shows an example selection of braking resistor to
output 100% of braking torque for each motor rating on list.