3-2
Chapter 3
Operation Setting and Examples of I/O Adjustment
Frequency source 1
3.3 Frequency setting from keypad
Select [AA101] = 07 :Parameter Setting.
(Frequency reference is selected by parameter setting.)
Changing frequency setting from each source
(1) [FA-01] “Main speed reference setting or monitor” or
(2) [Ab110] “Multi-speed 0 setting, 1st-motor”
Eg.) For [FA-01]
Frequency source
Use the up, down, left and right arrow keys to change
the frequency reference setting by [FA-01] “Main speed
reference setting or monitor” or [Ab110] “Multi speed
0 setting, 1st motor”.
Parameter
Parameter
Details
Setting
data
[AA101]
Main speed input source
selection, 1st-motor
07
[FA-01]*)
Main speed reference
setting or monitor
0.00Hz
[Ab110]*)
Multi-speed 0 setting,
1st-motor
0.00Hz
*) While [AA101] = 07, a change made in either [FA-01]
or [Ab110] will be automatically reflected in the
other. When no change can be made or is reflected
in [FA-01], the operator keypad is not specified as a
command source by the terminal function or
[AA101].
The frequency setting value should be set to other
than 0.00.
When the main speed command can be set on the
keypad, the output terminal 010[FREF]turns ON.
Run command source 1
3.4 Run key using on the keypad
Select [AA111] = 02 : keypads RUN-key.
Run/stop command
Press the RUN key and STOP key on the operator
keypad to start and stop the inverter, respectively.
Parameter
Parameter
Details
Setting data
[AA111]
Run command input
source selection,
1st-motor.
02
When the RUN command can be input from the
keypad, the output terminal [REF]Run
command=Keypad turns ON.
In addition, when the RUN command is input, not
limited to the RUN key on the keypad, the output
terminal 031[FR] starting contact signal turns ON.
−

Driving inverter requires a frequency reference and an operation command.
Set “Run command source” and “Frequency reference source” referring to this chapter.
(For more detailsPlease contact your supplier or local Hitachi inverter sales office.)