For parameter configuration
[dA-01] to [dA-41]
4.2 Monitor naming (Nomenclature)
4.3 Description of monitor functions
※For more detail, please contact your supplier or local
Hitachi sales office .
Monitors data list
■Monitor mode (d code)
dA-01 Output frequency
monitor
0.00~590.00(Hz)
<Actual frequency output>
dA-02 Output current monitor
0.0~655.35(A)
(0.00 to 6553.5(A)(SH1-1600H or
above))
dA-03 Rotation direction
monitor
0(stop)/1(0Hz output)/
2(forward)/3(reverse)
dA-04 Frequency reference
monitor (After calculation) *2)
-590.00~590.00(Hz)
<as target value>
dA-06 Output frequency scale
conversion monitor
dA-08
Detect speed monitor
-590.00~590.00(Hz)
<Encoder feedback required>
dA-12 Output frequency
monitor (signed)
dA-14 Frequency upper limit
monitor
dA-15 Torque reference
monitor (After calculation) *2)
-1000.0~1000.0(%)
<Torque control mode required>
dA-16 Torque limit monitor
dA-17 Output Torque monitor
*1)
dA-18 Output Voltage monitor
(RMS)
dA-20 Current position
monitor
When [AA121]≠10 or [AA123]≠03
-536870912 to +536870911 (pls)
Parameter setting other than above
-2147483648 to +2147483647(pls)
dA-26 Pulse train position
deviation monitor
-2147483647~+2147483647(pls)
dA-28 Pulse count monitor
dA-30 Input power monitor
0.0~655.35(kW)
(0.00 to 6553.5(kW)(SH1-1600H or
above))
dA-32 Accumulation input
power monitor
dA-34 Output power monitor
0.0~655.35(kW)
(0.00 to 6553.5(kW)(SH1-1600H or
above))
dA-36 Accumulated output
power monitor
dA-38 Motor temperature
monitor
-20.0 to 200.0 (degree Celsius)
dA-40 DC bus voltage monitor
dA-41 BRD load rating monitor
dA-42 Electronic thermal load
rating monitor (MTR)
dA-43 Electronic thermal load
rating monitor (CTL)
dA-45 Safety STO monitor *3)
00(no input)/01(P-1A)/
02(P-2A)/03(P-1b)/04(P-2b)/
05(P-1C)/06(P-2C)/07(STO)
dA-46 Safety Option Hardware
Monitor *3)
dA-47 Safety Option Function
Monitor *3)
00(no input )/ 01(STO)/
02(SBC)/03(SS1)/04(SLS)/
05(SDI)/06(SSM)
dA-50 Control terminal status
00(P1-TM)/02(P1-TM2)/
15(not connect)
dA-51
Input terminal monitor
A B 9 8 7 6 5 4 3 2 1
Input B,A,9,8,7,6,5,4,3,2&1:OFF
dA-54
Output terminal monitor
AL(-) 15 14 13 12 11
Output (-),14:ON
Output AL,15,13,12,
11:OFF
dA-60
Analog input/output status monitor
*4)
Ao4 Ao3 Ai4 Ai3 Ao2 Ao1 Ai2 Ai1
Teminal Ao4,Ao3, Ai4, Ai3,
Ao1,Ai2,Ai1:Voltage
Teminal Ao2:Current
dA-61 Analog input [Ai1] monitor
dA-62 Analog input [Ai2] monitor
dA-63 Analog input [Ai3] monitor
dA-64 Analog input [Ai4] monitor
dA-65 Analog input [Ai5] monitor
dA-66 Analog input [Ai6] monitor
dA-70 Pulse train input monitor
(internal)
dA-71 Pulse train input monitor
(option)
dA-81 Option slot-1 status
00:(none)/01:(P1-EN)/
02:(P1-ECT)/03:(P1-PN)/
05:(P1-DN)/06:(P1-PB) /
07:(P1-CCL)/18:(P1-AG)
33:(P1-FB)(only dA-82)
48:(P1-FS)(only dA-83) *5)
dA-82 Option slot-2 status
dA-83 Option slot-3 status
*1) dA-17 is invalid when the Control mode selection (AA121/AA221)
setting is 00 to 07 (V/f control mode).
*2) (After calculation) means that it is after calculation such as auxiliary
speed or addition frequency and calculation such as torque bias.
*3) For SH1 series, function safety is invalid.
*4) dA-60 is available also for the terminals of the option terminal
board.
*5)This option is not suitable for SH1 series.