For parameter configuration
[HA210] to [HA234]
2nd motor When Intelligent Input terminal 024[SET] is enabled.
HA210 Stabilization constant, 2nd-motor
HA112 Stabilization ramp function end
ratio, 2nd-motor
HA113 Stabilization ramp function start
ratio, 2nd-motor
HA215 Speed response, 2nd-motor
HA220 ASR gain switching mode selection,
2nd-motor
HA221 ASR gain switching time setting,
2nd-motor
HA222 ASR gain mapping intermediate
speed 1, 2nd-motor
HA223 ASR gain mapping intermediate
speed 2, 2nd-motor
HA224 ASR gain mapping maximum speed,
2nd-motor
HA225 ASR gain mapping P-gain 1,
2nd-motor
HA226 ASR gain mapping I-gain 1,
2nd-motor
HA227 ASR gain mapping P control P-gain 1,
2nd-motor
HA228 ASR gain mapping P-gain 2,
2nd-motor
HA229 ASR gain mapping I-gain 2,
2nd-motor
HA230 ASR gain mapping P control P-gain 2,
2nd-motor
HA231 ASR gain mapping P-gain 3,
2nd-motor
HA232 ASR gain mapping I-gain 3,
2nd-motor
HA233 ASR gain mapping P-gain 4,
2nd-motor
HA234 ASR gain mapping I-gain 4,
2nd-motor
[Hb102] to [Hb108]
Basic parameters for Induction motor
Hb102 Async.
Motor capacity
setting, 1st-motor
0.01 to
160.00 (kW)
(0.01 to
500.00(kW)
Motor capacity setting
(For the SH1-1600H or above
models, the maximum
setting range is 500.00
(kW). )
Hb103 Async.
Motor number of
poles setting,
1st-motor
0 to 23
( 2 poles to
48 poles )
Hb104 Async.
Motor base
frequency setting,
1st-motor
60.00(JPN)(USA)/
50.00(EU)(ASIA)(CHN)
Hb105 Async.
Motor maximum
frequency setting,
1st-motor
60.00(JPN)(USA)/
50.00(EU)(ASIA)(CHN)
Hb106 Async.
Motor rated
voltage, 1st-motor
(400V Class)
400(JPN)(EU)(ASIA)(CHN)
460(USA)
Hb108 Async.
Motor rated
current, 1st-motor
・If the motor capacity [Hb102] and number of poles
[Hb103] are changed, the motor characteristics are set
according to the internal Hitachi table values.
・The output is decided by setting the frequency and
voltage. Below there is an example of V/f control.
・By setting the motor rated current, a reference current
for the motor protection is set.
※Initial value depends on the inverter.
0.01 to 160.00 (kW)
(0.01 to 500(kW)
for SH1-1600H or above models)
0 to 23 (2 poles to 48 poles)
Motor rated
voltage
(Ex.) 400V