Page
Changes
3-32
B-7
OLD DEFAULT SETTING:
“C” Function
Run-
Defaults DOP,DRW,DOP+
Func.
Code
Name Description
time
Edit
EU/
US
Units
Func.
Code
Name
C31 Reserved Factory use only; do not
change
00
- F-35 OUT-TM
O/C-1
C32 Terminal 11
active state
Select logic convention, two
option codes:
00…normally open [NO]
01…normally closed [NC]
00
- F-35 OUT-TM
O/C-2
NEW DEFAULT SETTING:
*Inverters manufactured after the revision as defined in Note 1 will have the following settings:
“C” Function
Run-
Defaults DOP,DRW,DOP+
Func.
Code
Name Description
time
Edit
EU/
US
Units
Func.
Code
Name
C31 Terminal 11
active state
Select logic convention, two
option codes:
00…normally open [NO]
01…normally closed [NC]
00
- F-35 OUT-TM
O/C-1
C32 Terminal 12
active state
Select logic convention, two
option codes:
00…normally open [NO]
01…normally closed [NC]
00
- F-35 OUT-TM
O/C-2
OLD DEFAULT SETTING:
“C” Group Parameters Default Setting User Setting
Func. Code Name -FE(Europe) -FU(USA)
C31 Factory-set - -
C32 Terminal 11 active state 00 00
NEW DEFAULT SETTING:
*Inverters manufactured after the revision as defined in Note 1 will have the following settings:
“C” Group Parameters Default Setting User Setting
Func. Code Name -FE(Europe) -FU(USA)
C31 Terminal 11 active state 00 00
C32 Terminal 12 active state 00 00