Functions and User Friendly.
Inverter control by Built-in
Programming function
Simple sequence operation is realized by downloading to an
inverter the program created by programming soft EzSQ.
It is also possible to automatic speed control according to a load
situation like a swift lift function for crane or a conveyor, and to
operate.
Since an external circuit can be simplified, a control board is
made small and a cost cut can be aimed at.
Password function is added to prevent program information
leaks. This is also useful for unexpected data rewriting or
deletion by operation mistake.
Built-in EMC Filter
Cost and space reduction compared with external EMC Filter.
Reduces electromagnetic noise.
EN61800-3 2nd-Environment
Brake circuit up to 22kW
Cost and Space reduction compared with external Braking
Controller.
Internal Option
Programming [EzSQ: Easy Sequence] function
Example (110HFEF2)
Frequency [Hz]
Level [db]
[The example of a use] Example for Rely sequence
Current INV
SJ700
Current INV
SJ700
Operation
circuit
Programming window
EzSQ
Programming
Item Description
Language SpecI/O functionReserved word
Language type BASIC Like
Supported Device Windows(DOS/V)OS:Windows98SE,Windows2000,WindowsXP)
Programming
environment
Editor(Windows),Display(Windows)
Programmable flow control <Loop,Unconditional jump, conditional jump,
Time control, Sub routine, Others>
Operation command <+,-,,*, /, substitution, mod, abs>
I/O control(Bit input, Word input, Bit output, Word output)
Timer control <on delay, off delay>
Inverter parameter setting
User U(00)
-
U(31)/32 point
Timer UL(00)
-
UL(03)/4 point
Set frequency SET-Freq
Acceleration time ACCEL
Deceleration time DECEL
Monitor
Output frequency, Output current, Rotative direction,
PID feedback, Converted frequency, Output torque,
Output voltage, Power, Cumulative RUN time,
Cumulative power-on time, trip
General-purpose
input contact
X(00)
-
X(07)/8 point
General-purpose
output contact
Y(00)
-
Y(05)/6 point(1 point is relay output)
UB(00)
-
UB(07)/8 pointInternal user
TD(0)
-
TD(7)/8 point
Internal timer
contact
In a remote operator display code.
Inverter input
and output
Grammar check(Windows)
Program download/upload, All clear
Interpreter 2.0ms/command (Sub routine supported. 8 nested)
Memory area
Executable format
External input
External output
Command
Variable
1,024 steps or 6k byte
(Smaller of these)Program is stored in internal of inverter.
External digital
contact input
External analog
input
General-purpose
output terminal
Contact signal/Open collector signal input
(Internal DC24V power supply available)
Program RUN
command
FW terminal is reserved
General-purpose
input
Maximum of 8 point(X(00)
-
X(07))
XA(0) : 0
-
10V (O terminal)
XA(1) : 4
-
20mA (OI terminal)
XA(2) : 0
-
10V (O2 terminal)
External analog
output
YA(0) : Setup for FM terminal is possible.
YA(1) : Setup for AM terminal is possible.
YA(2) : Setup for AMI terminal is possible.
Maximum of 8 point(Y(00)
-
Y(05))
Download
QP: Quasi Peak
*
Windows
¨
is a registered trademark of Microsoft Corporation.U.S.A and other countries.