P033 6065 6066 Torque source setting for torque control X1 R/W Addr:0xA39C Sz: 1 Range:[0-3]
P034 6067 6068 Torque setting X1 R/W Addr:0xA39E Sz: 1 Range:[0-200]
P035 6069 6070 Torque character selection at O2 X1 R/W Addr:0xA39D Sz: 1 Range:[0-1]
P036 6071 6072 Torque bias source setting for torque contorl X1 R/W Addr:0xA3A0 Sz: 1 Range:[0-2]
P037 6073 6074 Torque bias setting X1 R/W Addr:0xA3A2 Sz: 2 Range:[-200-200]
P038 6075 6076 Torque bias character selection at O2 X1 R/W Addr:0xA3A1 Sz: 1 Range:[0-1]
P039 6077 6078 Speed limit (forward) setting on torque control X100 R/W Addr:0xA3A4 Sz: 4 Range:[0-40000]
P040 6079 6080 Speed limit (reverse) setting on torque control X100 R/W Addr:0xA3A8 Sz: 4 Range:[0-40000]
P044 6087 6088 Timer setting of communication timeout Whilst runn X100 R/W Addr:0x01F2 Sz: 2 Range:[0-9999]
P045 6089 6090 Inverter action When communication error (SJ-DN) X1 R/W Addr:0x01F6 Sz: 1 Range:[0-4]
P046 6091 6092 Polled I/O OUTPUT Instance number (SJ-DN) X1 R/W Addr:0x01F7 Sz: 1 Range:[20-100]
P047 6093 6094 Polled I/O INPUT Instance number (SJ-DN) X1 R/W Addr:0x01F8 Sz: 1 Range:[70-101]
P048 6095 6096 Inverter action when Idle mode detected (SJ-DN) X1 R/W Addr:0x01F5 Sz: 1 Range:[0-4]
P049 6097 6098 Motor poles setting for revolutions per minute (SJ X1 R/W Addr:0x01F4 Sz: 1 Range:[0-19]
P050 6099 6100 Output frequency on analog reference signal loss X1 R/W Addr:0x02DF Sz: 1 Range:[0-3]
P055 6109 6110 Filter time constant setting on pulse input X10 R/W Addr:0xA3B0 Sz: 2 Range:[10-500]
P056 6111 6112 Bias setting on pulse input X100 R/W Addr:0xA3B2 Sz: 1 Range:[1-200]
P057 6113 6114 Limit setting on puse input X1 R/W Addr:0xA3B3 Sz: 1 Range:[-100-100]
P058 6115 6116 Frequency scall setting on pulse input X1 R/W Addr:0xA3B4 Sz: 1 Range:[0-100]
P060 6119 6120 Absolute position 0 setting X1 RME R/W Addr:0xA3B8 Sz: 4 Range:[-1073741820-1073741820]
P061 6121 6122 Absolute position 1 setting X1 RME R/W Addr:0xA3BC Sz: 4 Range:[-1073741820-1073741820]
P062 6123 6124 Absolute position 2 setting X1 RME R/W Addr:0xA3C0 Sz: 4 Range:[-1073741820-1073741820]
P063 6125 6126 Absolute position 3 setting X1 RME R/W Addr:0xA3C4 Sz: 4 Range:[-1073741820-1073741820]
P064 6127 6128 Absolute position 4 setting X1 RME R/W Addr:0xA3C8 Sz: 4 Range:[-1073741820-1073741820]
P065 6129 6130 Absolute position 5 setting X1 RME R/W Addr:0xA3CC Sz: 4 Range:[-1073741820-1073741820]
P066 6131 6132 Absolute position 6 setting X1 RME R/W Addr:0xA3D0 Sz: 4 Range:[-1073741820-1073741820]
P067 6133 6134 Absolute position 7 setting X1 RME R/W Addr:0xA3D4 Sz: 4 Range:[-1073741820-1073741820]
P068 6135 6136 Absolute home position search mode selection X1 RME R/W Addr:0xA3E4 Sz: 1 Range:[0-2]
P069 6137 6138 Absolute home position search direction selection X1 RME R/W Addr:0xA3E5 Sz: 1 Range:[0-1]
P070 6139 6140 Absolute home position return speed (low) setting X100 RME R/W Addr:0xA3E0 Sz: 2 Range:[0-1000]
P071 6141 6142 Absolute home position return speed (high) setting X100 RME R/W Addr:0xA3E2 Sz: 2 Range:[0-40000]
P072 6143 6144 Position range(for ward) setting X1 RME R/W Addr:0xA3D8 Sz: 4 Range:[0-268435455]
P073 6145 6146 Position range(r everse) setting X1 RME R/W Addr:0xA3DC Sz: 4 Range:[-268435455-0]
P100 6199 6200 User parameter U00 setting for Eazy-Sequence funct X1 RME R/W Addr:0xA760 Sz: 2 Range:[0-65535]
P101 6201 6202 User parameter U01 setting for Eazy-Sequence funct X1 RME R/W Addr:0xA762 Sz: 2 Range:[0-65535]
P102 6203 6204 User parameter U02 setting for Eazy-Sequence funct X1 RME R/W Addr:0xA764 Sz: 2 Range:[0-65535]
P103 6205 6206 User parameter U03 setting for Eazy-Sequence funct X1 RME R/W Addr:0xA766 Sz: 2 Range:[0-65535]
P104 6207 6208 User parameter U04 setting for Eazy-Sequence funct X1 RME R/W Addr:0xA768 Sz: 2 Range:[0-65535]
P105 6209 6210 User parameter U05 setting for Eazy-Sequence funct X1 RME R/W Addr:0xA76A Sz: 2 Range:[0-65535]
P106 6211 6212 User parameter U06 setting for Eazy-Sequence funct X1 RME R/W Addr:0xA76C Sz: 2 Range:[0-65535]
P107 6213 6214 User parameter U07 setting for Eazy-Sequence funct X1 RME R/W Addr:0xA76E Sz: 2 Range:[0-65535]
P108 6215 6216 User parameter U08 setting for Eazy-Sequence funct X1 RME R/W Addr:0xA770 Sz: 2 Range:[0-65535]
P109 6217 6218 User parameter U09 setting for Eazy-Sequence funct X1 RME R/W Addr:0xA772 Sz: 2 Range:[0-65535]
P110 6219 6220 User parameter U10 setting for Eazy-Sequence funct X1 RME R/W Addr:0xA774 Sz: 2 Range:[0-65535]
P111 6221 6222 User parameter U11 setting for Eazy-Sequence funct X1 RME R/W Addr:0xA776 Sz: 2 Range:[0-65535]
P112 6223 6224 User parameter U12 setting for Eazy-Sequence funct X1 RME R/W Addr:0xA778 Sz: 2 Range:[0-65535]
P113 6225 6226 User parameter U13 setting for Eazy-Sequence funct X1 RME R/W Addr:0xA77A Sz: 2 Range:[0-65535]
P114 6227 6228 User parameter U14 setting for Eazy-Sequence funct X1 RME R/W Addr:0xA77C Sz: 2 Range:[0-65535]
P115 6229 6230 User parameter U15 setting for Eazy-Sequence funct X1 RME R/W Addr:0xA77E Sz: 2 Range:[0-65535]
P116 6231 6232 User parameter U16 setting for Eazy-Sequence funct X1 RME R/W Addr:0xA780 Sz: 2 Range:[0-65535]
P117 6233 6234 User parameter U17 setting for Eazy-Sequence funct X1 RME R/W Addr:0xA782 Sz: 2 Range:[0-65535]
P118 6235 6236 User parameter U18 setting for Eazy-Sequence funct X1 RME R/W Addr:0xA784 Sz: 2 Range:[0-65535]
P119 6237 6238 User parameter U19 setting for Eazy-Sequence funct X1 RME R/W Addr:0xA786 Sz: 2 Range:[0-65535]
P120 6239 6240 User parameter U20 setting for Eazy-Sequence funct X1 RME R/W Addr:0xA788 Sz: 2 Range:[0-65535]
P121 6241 6242 User parameter U21 setting for Eazy-Sequence funct X1 RME R/W Addr:0xA78A Sz: 2 Range:[0-65535]
P122 6243 6244 User parameter U22 setting for Eazy-Sequence funct X1 RME R/W Addr:0xA78C Sz: 2 Range:[0-65535]
P123 6245 6246 User parameter U23 setting for Eazy-Sequence funct X1 RME R/W Addr:0xA78E Sz: 2 Range:[0-65535]
P124 6247 6248 User parameter U24 setting for Eazy-Sequence funct X1 RME R/W Addr:0xA790 Sz: 2 Range:[0-65535]
P125 6249 6250 User parameter U25 setting for Eazy-Sequence funct X1 RME R/W Addr:0xA792 Sz: 2 Range:[0-65535]
P126 6251 6252 User parameter U26 setting for Eazy-Sequence funct X1 RME R/W Addr:0xA794 Sz: 2 Range:[0-65535]
P127 6253 6254 User parameter U27 setting for Eazy-Sequence funct X1 RME R/W Addr:0xA796 Sz: 2 Range:[0-65535]
P128 6255 6256 User parameter U28 setting for Eazy-Sequence funct X1 RME R/W Addr:0xA798 Sz: 2 Range:[0-65535]
P129 6257 6258 User parameter U29 setting for Eazy-Sequence funct X1 RME R/W Addr:0xA79A Sz: 2 Range:[0-65535]
P130 6259 6260 User parameter U30 setting for Eazy-Sequence funct X1 RME R/W Addr:0xA79C Sz: 2 Range:[0-65535]
P131 6261 6262 User parameter U31 setting for Eazy-Sequence funct X1 RME R/W Addr:0xA79E Sz: 2 Range:[0-65535]
R-Reference codes:
R001 7001 7002 +6 X1 RO Addr:0x8E10 Sz: 4 Range:[0-360000]
R002 7003 7004 Setting Frequency X1 RO Addr:0x8E14 Sz: 4 Range:[0-360000]
R004 7007 7008 Output Frequency X1 RO Addr:0x8E1C Sz: 4 Range:[0-360000]
R005 7009 7010 Direction of setting revolution X1 RME R/W Addr:0x8E20 Sz: 1 Range:[0-2]
R006 7011 7012 Direction of output revolution X1 RO Addr:0x8E21 Sz: 1 Range:[0-360000]
R007 7013 7014 Output information of terminal X1 RO Addr:0x8E24 Sz: 4 Range:[0-360000]
R008 7015 7016 Upper input information of terminal X1 RO Addr:0x8E28 Sz: 4 Range:[0-360000]
R010 7019 7020 Lower input information of terminal X1 RO Addr:0x8E2C Sz: 4 Range:[0-360000]
R011 7021 7022 Rated output current X1 RO Addr:0x8E34 Sz: 2 Range:[0-360000]