Chapter 2
Page 11 of 46
User Interface
The SJ-EN has six LEDs to convey module status and activity.
Four LEDs next to the RJ45 connector:
STATUS (GREEN) This LED will be ON whenever the SJ-EN is receiving proper power from the
inverter and the self diagnostics have shown the board to be functioning normally.
LINK (GREEN) This LED is ON when the SJ-EN is receiving valid Ethernet pulses.
ACTIVITY (GREEN) This LED is ON whenever there is Ethernet traffic in the cable.
ERROR (RED) This LED will be ON if the SJ-EN has failed due to a hardware watchdog timeout, or
the Ethernet communications has been absent for the software watchdog timeout period.
Two LEDs near the right edge of the board:
TXD This LED indicates communication from the SJ-EN to the inverter through the option port.
RXD This LED indicates communication to the SJ-EN from the inverter through the option port.
(These two LEDs may appear blinking or may appear steady ON due to the high blink rate.)