2-8  Installing the USP V 
Hitachi Universal Storage Platform V/VM Configuration Guide for SGI
®
 IRIX
® 
Host Attachment 
Configuring the USP V Fibre-Channel Ports 
Use LUN Manager software to configure the USP V fibre-channel ports with the 
appropriate fibre parameters. You select the appropriate settings for each 
USP V fibre-channel port based on the device to which the port is connected: 
Determine the topology parameters supported by the device, and set your 
topology accordingly. 
Figure 2-2 shows the LUN Manager panel for defining port parameters, and 
Table 2-3 explains the panel settings. For more information, see the Hitachi 
Universal Storage Platform V LUN Manager User’s Guide (MK-96RD615). 
Table 2-3  Fibre Parameter Settings for the USP V 
Fabric  Connection  Provides 
Enable FC-AL  FL-port (fabric port) 
Enable  Point-to-Point  F-port (fabric port) 
Disable FC-AL 
NL-port (private 
arbitrated loop) 
Disable Point-to-Point Not supported 
   
 
Note: The USP V supports up to 2048 LUs per fibre-channel port.  
 
   
 
Note: If you plan to connect different types of servers to the USP V via the 
same fabric switch, use the zoning function of the fabric switch. 
 
   
 
Note: Contact Hitachi Data Systems for information about port topology 
configurations supported by HBA/switch combinations. Not all switches support
F-port connection.