Do you have a question about the Hitachi VSP G1500 and is the answer not in the manual?
Model | VSP G1500 |
---|---|
Category | Enterprise Storage System |
Drive Types Supported | SSD, HDD |
RAID Levels Supported | RAID 5, RAID 6, RAID 10 |
Controller Type | Dual Active Controllers |
Connectivity | Fibre Channel (FC), iSCSI, FCoE |
Power Supply | Redundant Power Supplies |
Maximum Host Connectivity | 256 |
Data Reduction Features | Deduplication, Compression |
Operating System Compatibility | Windows, Linux, VMware |
Management Software | Hitachi Command Suite |
Cooling | Redundant Fans |
Warranty | 3 years standard warranty |
Form Factor | Rack-mounted |
Provides an overview of the Command Control Interface (CCI) software and its capabilities for managing Hitachi RAID storage systems.
Details the core CCI functionalities like in-system replication, remote replication, and data protection supported on all Hitachi RAID storage systems.
Describes system configurations using in-band and out-of-band methods, including connecting to an in-band CCI server via out-of-band.
Details how CCI allows user authentication by using operation authority and the mandatory nature of this function.
Explains how commands are executed complying with user operation authority when the user authentication function is enabled.
Explains how to prevent users from changing the configuration of the same resource simultaneously.
Provides instructions for starting CCI with one or two instances on UNIX systems, including service registration and startup scripts.
Details the process of starting CCI with one or two instances on Windows systems, including service registration and startup files.
Details operations for creating LDEVs of virtual volumes for Dynamic Provisioning and making them available to hosts.
Explains how to enable/disable iSCSI virtual port mode and set/delete virtual port numbers for iSCSI ports.
Covers operations for creating external volumes via Fibre Channel and iSCSI, including mapping and modifying options.
Explains how to prioritize host I/O operations for high-speed processing by specifying host HBA WWNs or iSCSI names.
Describes how to perform ShadowImage and TrueCopy operations by issuing commands from a server host.
Explains how to perform Hitachi Thin Image operations by issuing raidcom commands to create snapshots.
Illustrates ShadowImage configuration and lists sample ShadowImage functions executable via CCI commands.
Explains how CCI TrueCopy commands operate with server software and TrueCopy functions for backup and failover.
Explains how Copy-on-Write Snapshot normally creates virtual volumes for copying on write.
Details how to control Volume Migration, including external volumes, using CLI and compatible modes.
Explains how the Data Protection Facility permits main operations to volumes and controls protected volumes via LUN Security.
Provides general troubleshooting advice for CCI software, including checking server hardware/software and restarting.
Lists system log messages and command error messages with recommended actions for resolving error conditions.
Provides information on contacting customer support, including necessary details to provide for problem resolution.