--- 20 ---
12-5. Tightening Torque
Tighten the screws and the bolts according to the following tightening torque.
12-6. Insulation Tests
On completion of disassembly and repair, measure the insulation resistance and dielectric strength.
Insulation resistance: 7 MΩ or more with DC 500 V megohm tester
Dielectric strength: AC 4000 V/1 minute, with no abnormalities
....
230 V
12-7. No-load Current Value
After no-load operation for 30 minutes, the no-load current value should be as follows.
Voltage
Current (Max.)
230 V
1.2
9.8
+ 2.0
N•m (100
+ 20
kgf•cm)
2.9 0.5 N•m (30 5 kgf•cm)Hex. Hd. Tapping Screw
Seal Lock Screw (W/SP. Washer)
Tapping Screw
Machine Screw (W/Washers)
Nylock Flat Hd. Screw
Hex. Socket Hd. Bolt (W/Flange)
1.8 0.4 N•m (18 4 kgf•cm)
1 0.2 N•m (10 2 kgf•cm)
3.4 0.7 N•m (35 7 kgf•cm)
2.2 0.4 N•m (22 4 kgf•cm)
3.4 0.7 N•m (35 7 kgf•cm)
Nylock Bolt (W/Flange) 5.9
+ 1.5
N•m (60
+ 15
kgf•cm)
Nylock Bolt (W/Flange) 5.9
+ 1.5
N•m (60
+ 15
kgf•cm)
Hex. Socket Hd. Bolt (W/Flange) 5.9 1.5 N•m (60 15 kgf•cm)
Nylock Bolt (W/Flange)
Hex. Socket Hd. Bolt (W/Flange) 22.1 4.9 N•m (225 50 kgf•cm)
Seal Lock Hex. Socket Hd. Bolt 39.2 7.84 N•m (400 80 kgf•cm)
2.0 0.5 N•m (20 5 kgf•cm)Tapping Screw (W/Flange)
D4 x 20 (Black) [42]
Tapping Screw (W/Flange)
M4 x 12 [3]
2.9 0.5 N•m (30 5 kgf•cm)
D5 x 20 (Black) [108]
D5 x 20 (Black) [111]
M4 x 10 [55]
M5 x 20 (Black) [122]
M4 x 8 [24]
M4 x 12 (Black) [28]
M5 x 16 [6]
M5 x 25 [37]
M5 x 30 [97]
M6 x 16 [56]
M8 x 25 [16]
M12 x 20 [81]
0
0
0
0
0
0
Tightening torqueSize and length