[P022]
Feed forward gain for APR control mode
[P023]
Position loop gain for APR control mode
[P025]
Secondary resistance compensation
00 : No compensation
01 : With compensation
Connect a motor thermistor between TH and CM1
terminal of the control card.
Set [b098] to a suitable value
s 00 : Thermistor input invalid
s 01 : PTC type
s 02 : NTC type
ƒ Set the resistance value [] you want to make it trip.
Set gain adjustment by [C085]
[P026]
Over speed trip level (%) setting
Inverter trips with over speed (E 61 or E 71) when a deviation between actual speed and target speed
exceeds the level of (Maximum frequency set) x [P026].
This can happen by an overshoot caused by incorrect settings of J ([H024]/[H034]) and/or K([H005]) value.
[P027]
Over deviation detection level (Hz) setting
Inverter gives out warning (DSE output) from an intelligent input terminal when the speed deviation exceeds
this level. The calculation is based on a deviation
ε
in Fig 7 and Fig 8.
Refer to section (4-2) for
an information.
Fig 15. Example of thermistor characteristics
Small [C085]
Big [C085]
20k
50
Internally calculated
resistance
Detected value from thermistor
(= Pulse count numbers in MCU)
NTC type
Small [C085]
Big [C085]
20k
50
Internally calculated
resistance
Detected value from thermistor
(= Pulse count numbers in MCU)
PTC type
[C085] = 0[C085] = 0