Number Item Description
Blink red: Failure with the
power supply unit of the
controller.
Amber: LAN reset switch
was pressed.
9 LAN-RST switch Use only when instructed by
customer support.
10 STATUS LED (for BKMF) Green: Charging of the
battery in the backup module
is complete.
Red: Backup module can be
removed.
Blink red one time: Main
battery failure.
Blink red two times: Backup
battery failure.
Blink red three times: Both
batteries failed or preventive
maintenance replacement of
batteries can run.
Off: Battery is not mounted,
battery-mounting failure
occurred, or firmware is
being upgraded. Off is
normal status for
configurations without
batteries (for example,
BKMF-10 and BKMF-20).
CBLH rear panel
The following table describes the definitions of the CBLH controller rear panel LEDs.
CBLH rear panel
Chapter 2: Virtual Storage Platform N800 controller
VSP N800 Hardware Reference Guide 20