MA99UE17-1804
15
7. LAK4D Series (UL):
7.1 LAK4D can combine uniaxial to 4-axial linear actuator.
7.2 The output power of a controller is 72.5VA (The output voltage is 24VDC).
7.3 A bolt is provided to avoid actuators cord and pluggable AC power cord from accidentally being removed
as well as reduce the danger when using.
7.4 LAK4D can combine with HIWIN linear actuator LAN5, and has an anti-loose function to prevent an actuator
from being removed; it is saving space and easy to install. (Please refer to the figure below)
7.5 LED power display.
7.6 Fuse specification2A/20mm(220/230VAC)
3A/20mm(100/110VAC).
7.7 The protective rank of anti-shock of this product is BF.
7.8 The sign on the case of this product indicates that here is a function forFunctional Ground.(For the
momentwe dont provide the function).
8. LAK6B Series:
8.1 Combine uniaxial to 6-axial actuators, and provide an intelligent controller as well as application software
according to customer requirements.
8.2 The output power of a controller is 216VA (The output voltage is 24VDC.).
8.3 3Ah lead acid batteries can be selected, built-in auto charge circuit without an external charger.
8.4 Over current protection and slow start.
8.5 Energy-saving device and replaceable fuse with spare one on a socket.
8.6 External grounding and LED power indication.
8.7 Fuse specification4A/20mm(100/110/220/230VAC).