8
2. Installation Guide
2.1 Please ensure that the extension tube is in the "lowest position" before installing actuators.
2.1.1 The term "lowest position" in this user's guide refers to the position such that there is no further
movement towards the DC motor while the actuator is powered on. (Please refer to the figure
below.)
2.1.2 External limit switch: For installing an external limit switch, please ensure the extension tube
is in the lowest position before installing an actuator (Please refer to the figure below.).
※ If an actuator doesn't have an external limit switch installed, you must install the stroke limiter on an actuator yourself.
The distance between two actuator limit switches can't be longer than the stroke of the actuator. And then rotate the
extension tube to adjust the length of an actuator, which can meet the minimum requirements to install actuators.
※ To avoid any wrong movements of actuators, there shouldn't have any magnetic materials close to external limit
switches within 30mm.