Programming Menu - Continued
Default Eng. Code - 4567 Default User Code - 1111 (Irl) 1234 (UK)
7 Output Menu
1 Panel Outputs
3 PSU Outputs
4 Output Card Outputs
5 Output Groups
6 User Outputs
2 Expander Outputs
5 Partset Options Menu
8 System Options
Menu
9 Comms Menu
1 Final Door Set NO
2 Exit Fault Bell YES
3 Line Fault Bell NO
4 Inhibit Tamper NO
5 Forced Arm YES
6 Display Armed YES
7 Extend Block Exit Time NO
8 Rearm Always NO
10 Arm Squawk NO
11 Infinite Exit NO
9 Rearm Count 3
1 Arming Options Menu
2 Unset Options Menu
3 Quick Key Menu
4 Keypad PA Options Menu
6 Miscellaneous Options Menu
7 Audio Options Menu
8 Edit Miscellaneous Text
9 Garda Policy Option
9 BS8423 Options (UK only)
(UK only)
1 User Walk Test YES
2 Fire Output Enabled YES
5 Fire Exit Require Code YES
6 Tamper Rearm YES
3 Extend Block Entry Time NO
4 Fire Exit Bells NO
1 Quick # Key Menu
1 Keypad * & # PA YES
1 Mains Fault Buzzer YES
1 Output Names
1 Pre-Alarm YES
1 Police Options
2 Quick Key Menu
2 Keypad PA Silent NO
2 Line Fault Buzzer YES
2 Output Options
2 Bell Tamp: Verified Alarm NO
2 Technistore Options
3 Silent PA Line Fault YES
3 FTC Buzzer YES
4 Fault Alert Buzzer NO
3 Alarm Abort Time 00
4 Restricted Indication YES
1 Timed Soak NO
1 Part Set A Exit Time NO
1 Edit Installer’s Name
2 Edit Block Names
2 Engineer Lock NO
2 Part Set B Exit Time YES
3 Duress Codes NO
3 Access to Exit Entry NO
3 Edit Part Set A Text
4 Walk Test Bell NO
4 Part Set Digi Alarm YES
4 Edit Part Set B Text
5 System Double Knock NO
6 Part Set A Exit Buzzer NO
8 Part Set A Entry/Exit to Alarm NO
9 Part Set B Entry/Exit to Alarm NO
6 Latch Chime NO
7 Part Set B Exit Buzzer YES
7 Internal Bell Chime NO
5 Indicate Part Set YES
5 Edit Fire Exit Message
6 Edit Fire Exit Type
7 Edit Technical Type
8 Edit Site Name
8 Auto Hour Change YES
9 Work to EN 50131 YES
10 Silent Fire NO
QUICK KEY MENU
0#1 User Log 0*1 SMS Engineers
0#3 Walk Test 0*2 SMS Log
0#4 Full Arm 0*3 Call PC
0#5 Quick Arm 0*4 PC Direct
0#6 Toggle Chime 0*5 User Check
0#7 Part Set A 0*6 Temporary User
0#8 Part Set B 0*7 Home Alone
0#9 Bell Test 0*8 Outputs
01 Pre-alarm
1 PSU51 Outputs
1 OPC51 Outputs
1 EXP1 Outputs
-ve
+ve
+ve
02 Alarm
05 External Bell
20 PSU85 Outputs
20 OPC85 Outputs
13 EXP13 Outputs
.. .. ..
.. .. ..
.. .. ..
.. .. ..
OUTPUT OPTIONS
Light
Partguard
Latch
Fire Reset
Perimeter
Tamper
Buzzer
Trouble
Tech 1
.. ..
Tech 8
Fire Exit 1
.. .. ..
Fire Exit 12
Block 1 Buzzer
.. .. ..
Block 8 Buzzer
Pre-Alarm
Block 1 Pre-Alarm
.. .. .. ..
Block 8 Pre-Alarm
Alarm Abort
Block 1 Alarm Abort
.. .. .. ..
Block 8 Alarm Abort
Mains Delay
Unexpected Open
Unexpected Close
Auto-activate
User Alert
SmartLight
SmartDoor
Unused
*UK only
Line Fault
Inhibit
B0 Inhibit
.. ..
B8 Inhibit
Force GSM
Zone/Point MAP
Pulse Gate
Heat
Gates
Aux
Free to Use
Panic Confirmed*
Sensor Reset
Internal Bell
External Bell
Alarm
Arm /Disarm
Fire
Panic Alarm
Strobe
B1 Alarm
.. ..
B8 Alarm
B0 Arm/Disarm
.. .. ..
B8 Arm/Disarm
B1 Internal Bell
.. .. ..
B8 Internal Bell
B1 External Bell
.. .. ..
B8 External Bell
B1 Strobe
.. ..
B8 Strobe
2 Communicators
1 Comms Overview
See next page
See next page
See next page
3 Monitoring & Voice
4 SMS Menu
5 Remote User Menu
6 Panel Print Menu
7 Serial Port Equip. Menu
8 SecureComm Menu
1 Remote User Codes
2 Remote User Names
3 Remote User Options
4 Remote User Phones
1 Print Engineer Log
2 Printer Options
1 Status
2 Disable
3 Options
4 Printer Port
REMOTE USER OPTIONS
Call Back
Remote Set
Remote Unset
NO
NO
NO
Default Engineer Code - 4567
Default User Code (IRL) - 1111
Default User Code (UK) - 1234
From previous page
10