Programming Menu
Default Eng. Code - 4567 Default User Code - 1111 (Irl) 1234 (UK)
2 Devices Menu
1 Service Menu
3 Zone Menu
2 Wired Devices Menu
1 Add & Identify Devices
1 Zone Names
6 Default ID Bus
5 Default Expanders
7 Default RF
1 Default All
2 Default Users
3 Default Comms
1 RF Devices Menu
2 Locate Devices
2 Zone Types
3 Remove Devices
4 Keypad Config. Menu
5 Expander Options Menu
6 Remote Names Menu
7 Output Card Options
3 Zone Options
4 Zone Gross & Pulse
5 Zone Hardware
6 Zone Block Assign
7 Technical Zone Options
8 Zone Map menu
4 Point Menu
6 Timers Menu
Please turn over
for...
5 Users Menu
1 Point Names
1 Set Time & Date
5 Event Timers
6 Smart Lights
7 Smart Doors
4 Block Timers
1 User Codes
2 Point Types
2 System Timers
2 User Names
3 Point Options
3 Miscellaneous Timers
3 User Options
4 Point Gross & Pulse
5 Point Block Assign
6 Point Map Menu
4 Engineer Code
5 User Block Assign
6 User Prox Assign
7 Manufacturer’s Code
1 Never Log NO
01 Non EOL
1 Zone Name Text
1 Point Name Text
1 Mapped Outputs
1 Mapped Outputs
1 Entry Timers
2 Only Log at Setting NO
02 Single EOL
2 Zone Audio
2 Point Audio
2 Mapped Output Options
2 Mapped Output Options
2 Exit Timers
3 Internal Bell Timers
4 External Bell Timers
3 Show Open before Set NO
03 Dual EOL 4K7
0X Dual EOL 2K2
4 Inhibit Required NO
0X Point ID
0X RF Device
0X RFI Device
dd/mm/yy hh:mm
1 Weeks to Service 00
1 Internal Bell 15
2 Fire Exit Delay 00
3 Mains Fault Delay 55
2 External Bell 15
3 Strobe Time 00
4 Entry Time 30
5 Exit Time 30
6 Split Entry Time 30
7 Soak Period 00
8 Bell Delay 00
9 Double Knock Reset 05
0 Double Knock Open 10
USER OPTIONS
EVENT TIMER TYPES
Full Set User Menu
Unset Manager Menu
Inhibit Output Only
Part Set A 24 Hour
Part Set B Code & Prox
Unused Auto-Arm Part Set A
Open/Closed Auto-Arm Part Set B
Home Alone Timed Access
Auto-Activate User Alert
Auto-Arm Full
2 Battery Load Test
2 Full Set ?
2 Log Menu
1 Unset ?
1 System Overview
4 Default Wired Keypads
3 Quick Arm ?
3 Engineering Tools Menu
4 Part Set A ?
4 Engineer Arm/Disarm
5 Part Set B ?
5 Defaults Menu
7 Voice Demo Menu
8 Remote Service
1 Battery Current Monitor
2 Test Digi Channels
3 Test Extended Reports
1 Test Outputs
8 Battery Menu
9 Bell Test
10 Zone Resistance
5 RF SABB Status
6 RF Wand Status
7 RF Keypad Status
1 RF Device Status
1 RF Zone Status
1 Image Size
2 RF Point Status
2 Colour
2 Open Inputs Menu
3 Walk Test Menu
4 Show System Faults
3 RF Keyfob Status
3 Number of Images
5 Test Outputs & Channels
6 Test RF Devices
7 Show Software Versions
4 RF Echo Status
4 Live Images
1 Add & Identify RF Devices
2 Locate RF Devices
3 Remove RF Devices
4 RF Device Options
5 RF System Options
6 RF Camera Options
Inhibit
Access
Excl. from Part Set A
Excl. from Part Set B
Double Knock
Soak
Chime
24 Hour
Perimeter
Remote Test
Inhibit
Excl. from Part Set A
Excl. from Part Set B
Soak
Chime
Disable BV
Remote Test
Inhibit
Soak
Silent PA
Remote Test
Inhibit
Soak
Remote Test
Soak
Key Pulse
Remote Test
Inhibit
Soak
24 Hour
Fire Exit Delay
Remote Test
None
Remote Test
Unset
Remote Test
Inhibit
Soak
24 Hour
Remote Test
ZONE/POINT TYPES vs OPTIONS
Alarm
Entry / Exit
Panic
Fire
Tamper
Gas
Key
Key Partset A
Key Partset B
Fire Exit
Exit Terminator
Shunt Lock
Line Fault
Fail To Communicate
Technical
ZONE & POINT TYPES
Alarm
Entry/Exit
Panic
Fire
Tamper
Key
Line Fault
Fail to Connect
Unused
Technical 1
.. ..
Technical 8
Exit Terminator
Gas
Shunt Lock*
*UK only
Fire Exit 1
.. .. ..
Fire Exit 12
Key Part Set A
Key Part Set B
MAPPED OUTPUT OPTIONS
Unset Disable Y/N Latched Output Y/N
Pulsed Output Y/N Output Trip Time (sec)
TR
ZONE 2
6 Firmware Upgrade
8 System Options
Menu
9 Comms Menu
9
For adjusting RF-PIR sensitivity,
activating/deactivating the MC’s in
RF-Contact/Sensors, turning on
the “Unset via User-code” feature
on the key-fob, adjusting the RF-
Echo volume, controlling the flash
on the RF-PIRCAM etc.