EasyManua.ls Logo

Hobart Welders Handler 210 - Process;Polarity Table; Changing Polarity

Hobart Welders Handler 210
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OM-227 978 Page 12
5-3. Process/Polarity Table
Process
Polarity
Cable Connections
P
rocess
P
o
l
ar
i
ty
Cable To Gun Cable To Work
GMAW Solid wire with shield-
ing gas
DCEP Reverse polarity Connect to positive (+) out-
put terminal
Connect to negative () output
terminal
FCAW Self-shielding wire
no shielding gas
DCEN Straight Polarity Connect to negative ()
output terminal
Connect to positive (+) output
terminal
CHANGING
POLARITY
5-4. Changing Polarity
1 Lead Connections For Direct
Current Electrode Negative
(DCEN)
2 Lead Connections For Direct
Current Electrode Positive
(DCEP)
Always read and follow wire
manufacturer’s recommended
polarity, and see Section 5-3.
Close door.
Ref. 209 228 / Ref. 209 229
1
2
DCEN
Electrode negative for
flux cored wire
DCEP
Electrode positive for
solid wire