BA-21426-002-EN 06.08.2010 17
EN
According to the issue, a code will be shown in the upper display
(see table below).
Die ON/OFF-Button
flashes GREEN/RED alternately – restricted operation may be possible:
CODE POSSIBLE CAUSE MEASURES
AL Drain hose is blocked. Restart drain cycle. Clean drain hose if necessary.
HEI Rinse booster heating defective. Call the after sales service.
d 0 OPTION: External demineralisation cartridge depleted. Replace cartridge.
SAL
Salt deficiency (only with built-in softener) Refill the softener with granular regeneration salt.
Die ON/OFF-Button
illuminates RED and the Service indicator
illuminates:
CODE POSSIBLE CAUSE MEASURES
FIL Shut-off valve is closed. Open shut-off valve at site and switch on machine again.
Fill valve or fill system defective. Call the after sales service.
SIE Tank strainer not correctly positioned. Put strainer correctly in place.
UL Drain hose blocked. Restart drain cycle. Clean drain hose if necessary.
Fill system or drain system defective. Call the after sales service.
F01 - -1/- -2 Temperature probe "rinse booster" defective. Call the after sales service.
F02 - -1/- -2 Temperature probe "tank" defective. Call the after sales service.
F03 - -1/- -2 Pressure transmitter "rinse booster" defective. Call the after sales service.
F04 - -1/- -2 Pressure transmitter "tank" defective. Call the after sales service.
F04 - -3/- -4 Pressure transmitter tank fault 1. Drain machine and refill.
2. Call the after sales service.
ERR Communication fault. Call the after sales service.
OTHER INDICATIONS
CODE POSSIBLE CAUSE MEASURES
CH1
DOS
Detergent deficiency. Replace container, respectively, fill optional integrated
container. After container replacement, it can take sev-
eral wash cycles until the indicator goes out. If required,
hose priming should be carried out according to section
3.4.
CH2 Rinse aid deficiency.
7. FAULTS/INDICATIONS