Do you have a question about the Hobart M802 and is the answer not in the manual?
Capacity | 80 quarts |
---|---|
Bowl Lift | Manual |
Phase | 3 |
Voltage | 208/230/460 V |
Speeds | 4 fixed speeds |
Procedures for unpacking the mixer and checking for shipping damage.
Guidance on selecting an operating location, space requirements, and leveling the mixer.
Instructions to check oil levels in the transmission and planetary before starting.
Guidelines for electrical and grounding connections, including warnings.
Procedure to verify correct motor rotation for three-phase models.
Explanation of the start, stop, and timer functions for electro-mechanical controls.
Overview of the programmable timer controller and its display.
How to use preset keys P1 and P2 to select or adjust mixing times.
Steps to modify and save preset mixing times for P1 and P2 keys.
Instructions for using the clutch and gear shift levers to change mixer speeds.
How to operate the power bowl lift lever to raise or lower the bowl.
Procedures for cleaning and installing mixer bowls and agitators.
Details on rotating, removing, and reinstalling the wire cage and splash guard.
How to install and operate attachments using the attachment hub.
Description of the four available mixer speed settings and their typical uses.
Mentions a separate manual for the bowl scraper attachment.
General instructions for cleaning the mixer, bowls, and agitators.
Procedures for checking and filling the planetary oil level.
Instructions for checking and filling the transmission oil level using the oil level gauge.
Lubrication points for the bowl lift mechanism, slideways, and lift screw.
How to adjust the bowl clamp height using the lock nut.
Procedures for checking and adjusting agitator-to-bowl clearance.
Lists common mixer symptoms and their potential causes.
Information on contacting the Hobart Service Office for repairs.