2 6 C o n f i g u r a t i o n
HP-327 HIT-4U
Configuration Fields Description
SYSTEM MENU
Menu
Item
Description Options Min
Max
Value
Default
CLEAR
Clear Total and
save new value
(0) to EEPROM.
Grand Total is
non-resettable.
NO
YES
N/A NO
SETTOT
Set Total and
save to
EEPROM.
Numeric
Entry
0
99999999
0
SW VER
Read-only
displays HIT-4U
software version.
N/a N/A N/A
DATE
Current Date
(mm-dd-yy)
mm-dd-yy N/A 01-01-10
TIME
Current time in
24-hour format.
hh-mm-ss N/A 23-00-00
ID NUM
HIT-4U Serial
Number
Numeric
Entry
0
99999999
1234567
PASSWD Password
0000 –
9999
0000
9999
1234
LOCK
Password
protected
NO (0)
YES (1)
N/A NO
SMPL T
Sample
Time
1-80
1
80 (8 sec.)
1
CONTHR
Contract Hour
for daily logs
1-24 1 1 (1 AM)
HR LOG
Displays Hourly
Logs
Incremental
Scroll
1
(previous
hour)
99
0
(current)
DAYLOG
Displays Daily
Logs
Incremental
Scroll
1
(yesterday)
99
0
(current)